Spec Sheet for the Steppe: Combining Cold-Start and Altitude Packages for Central Asian Open Pits
A Central Asian open pit in January gives a Diesel Compressor two problems at once: a cold enough start to kill the fuel system, and an altitude high enough to take the power off it. They are separate engineering problems, and the spec sheet has to answer both.
TL;DR
- Cold start and altitude are two different deratings, and a machine derated for one is still wrong for the other. Altitude takes power away from you; cold takes the fuel away from you.
- Altitude is a percentage, and it is predictable. The usable percentage of rated power is fixed by the site's elevation above sea level, and it can be written into the specification as a number.
- Cold start is a fuel system question, not an engine output question. The specification items that decide it are the fuel grade, the pour point of that grade at your lowest temperature, and the pre-heating arrangement.
- The two packages combine in one line on the spec sheet: the compressor is rated at the site altitude, the fuel system is rated at the site low temperature, and the cooling package is rated at the site summer ambient.
- Our Mobile Diesel Compressors cover 7/25 bar at 10–35 m³/min, and the KG520 and KG520H down-the-hole rigs carry their own compressor for high-altitude open-pit work.
The short answer: specify the machine against three separate site numbers — elevation, lowest winter temperature and highest summer ambient — and require the supplier to state the derate for each. Our compressors for extreme climate sites are built for exactly this conversation, and the KG520 and KG520H down-the-hole drill rig for open pits is the reference case for how a drilling package is specified for a high, cold site.
Line One: Altitude, and Why It Is a Number You Can Write Down
Altitude is the easiest part of the whole specification, because the derate is a percentage that follows from the site elevation and nothing else. It is also the part most often left to the supplier to guess.
What the air does
Air thins with altitude. What does not change is how much oxygen the engine needs to burn a given amount of fuel, so a naturally aspirated diesel that made rated power at sea level simply cannot make it at 3,000 metres. The deficit is roughly 3% for every 300 metres above the engine's rated test altitude, which for a typical industrial diesel rated at 1,500 metres means the derate starts from there and runs at roughly 1% per 100 metres above it.
Turbochargers help, and do not eliminate it
There is a second altitude effect that is easy to miss and that I would always raise with a customer: at altitude the air is drier, and drier intake air means more dust, because there is less moisture to bind particles. Because a compressor working at 3,000 metres breathes dustier air than the same machine at sea level, the air filter specification at a high-altitude site is not a copy of the low-altitude one.
What this means for a compressor
A mobile diesel compressor loses output at altitude in exactly the way a diesel engine does, because the compressor is driven by one. A unit rated at 10 m³/min at 7 bar at sea level does not deliver 10 m³/min at 3,000 metres. The derated figure is what the site consumes, and if the operator sizes a pipeline or a drill cycle against the sea-level figure, the shortfall appears as a slow cycle and a hot machine.
Because the rated flow and the rated pressure are quoted at sea level, and because the site consumes the derated figure, the specification has to state the flow at site elevation or the operating department will plan against a number the machine cannot deliver.
Line Two: Cold Start, Which Is a Fuel System Problem
Cold does not reduce the power a diesel engine makes. It prevents it from starting, and then it makes the fuel system fail once it is running. That is why cold start and altitude are separate line items on a spec sheet even though they arrive at the same site on the same day.
What actually fails in the cold
Three things, in order of how often they occur:
Because the pour point of the fuel grade is a property of the grade and the site temperature is a property of the site, their comparison is a comparison of two published numbers, and it should appear on the spec sheet as a comparison rather than as an assumption.
The two standards that matter for the fuel
Two test methods are the ones to specify by name. ASTM D975 is the standard specification for diesel fuel oils and carries the pour point requirement, and it is the reference that a fuel supplier will quote against. ASTM D4054 covers the low temperature properties of diesel fuels and gives the flow properties that determine whether the fuel will move through the system in cold conditions.
Where the compressor differs from the drilling rig
A compressor is a stationary duty machine that starts, runs continuously and stops at the end of shift. A drill rig is a machine that gets started and stopped many times a day, in the worst conditions of the year, often before sunrise and often in the open.
Because a drill rig's starting frequency and its exposure are both higher than a compressor's, the pre-heating package on a rig is sized more generously than the package on a compressor for the same site, and the two should not be quoted as one line item.
Line Three: The Cooling Package, Which Nobody Specs Until Summer
A machine specified for a January site and then operated in a July site has been specified for a climate that does not exist. The steppe has the largest temperature swing of any region I work in, and it is where the cooling package gets left out.
The three temperatures, and they are not interchangeable
- The cold temperature sets the fuel spec and the pre-heating, and it is the one the site engineer thinks about.
- The hot temperature sets the cooling spec, and it is the one nobody asks for.
- The average temperature sets the oil change interval and the filter service interval, because hours and ambient together determine how much the oil degrades.
What a compressed air machine does about it
Our published guidance is that discharge air temperature should stay below 100 °C at full load during daily checks, and that above 105 °C at full load is an immediate shutdown signal. That band is narrow, and it is narrow because the machine is already close to its limit in normal conditions.
Because the shutdown threshold and the normal operating band are only 5 K apart at the top end, and because a high-altitude site also lowers the cooling margin, a compressor derated for altitude and specified for a mild summer will reach that band in ordinary operation.
The site dirt is the third variable
Open pit air carries dust, and at altitude it carries more of it. The air filter service indicator is the daily check on the intake side, and a filter that stays in the green zone is what keeps the machine's airflow and therefore its cooling performance intact.
Because the filter protects both the airend and the cooling path, the filter specification is part of the climate package rather than a consumable line item, and a site specification that omits it has left a hole in the cooling calculation.
Frequently Asked Questions
Do I need a separate cold-start package for a Central Asian open pit?
Usually yes, and the deciding factor is the fuel rather than the engine. Compare the pour point of the fuel grade specified against the site's lowest recorded temperature, with a margin, and if the two are close then the fuel system specification has to change regardless of what the engine can do. Beyond that, the cold-start items are the cranking oil viscosity, the battery type and the pre-heating arrangement, and all three are order-time decisions that are expensive to change in the field.
How much power does a diesel compressor lose at altitude?
It depends on the elevation, whether the engine is turbocharged or naturally aspirated, and the rated test altitude of the engine. As a rule of thumb the loss runs at roughly 3% for every 300 metres above the engine's rated test altitude, and a turbocharged unit recovers most of that but not all of it. Because the compressor is driven by the engine, the airflow it delivers falls with it, so a machine rated at 10 m3/min at sea level does not deliver 10 m3/min on a 3,000 metre plateau. The specification has to state the flow at site elevation.
Does a high-altitude site need a different air filter?
It needs a filter decision that was made with the altitude in mind rather than copied. Air is drier at altitude, and dry air carries more dust because there is less moisture to bind the particles, so the loading rate on an intake filter at 3,000 metres is higher than the same filter at sea level. The service indicator stays in the green zone on a correctly sized filter, and that is what protects both the airend and the cooling path at the same time.
What should a spec sheet contain for a cold, high open pit?
Three site numbers and four answers. The site numbers are elevation, lowest winter temperature and highest summer ambient. The answers are the rated flow at site elevation, the fuel grade and its pour point margin against the lowest temperature, the cold-start package including pre-heating and cranking oil and battery, and the cooling package rated against the summer maximum. Our mobile diesel range covers 7/25 bar at 10 to 35 m3/min, and the drilling packages carry their own compressor, so the two lines are specified against the same three site numbers.
Can a compressor specified for a temperate climate be derated for altitude on site?
The power can be derated, but the packaging cannot. Altitude derating is an engine characteristic that applies to the machine as delivered, and a turbocharger's boost limiter has to be set for the site's elevation rather than left at its factory setting. The cold-start package, the fuel grade and the cooling package are not deratings at all, they are different specifications. This is why the three site numbers have to arrive with the enquiry rather than being established after the machine has shipped.
Which Approach Should You Take?
Send three site numbers and get four answers back, before the machine is ordered. Elevation, lowest winter temperature, highest summer ambient — and in return, the flow at site elevation, the fuel grade with its pour point margin, the cold-start package and the cooling package.
Because altitude is a percentage you can calculate and cold is a fuel specification you have to choose, the two are handled at different stages and by different people, and the one that is easiest to fix is also the one that gets skipped.
Our compressors for extreme climate sites are specified against the site rather than against the catalogue, and the KG520 and KG520H down-the-hole drill rig for open pits is the same discipline applied to a drilling package, where the compressor on the deck and the machine around it have to be rated against one site, not two.
I have spent more than twenty years matching compressors and drilling equipment to field conditions rather than catalogue assumptions, and the pattern in Central Asia is consistent. Because the site numbers cost nothing to send and a winter shutdown costs a season, the numbers should be in the first enquiry and not in the second.
Request a Cold-Climate Spec Review
To talk through a cold-start and altitude package, contact Mr. YU on WhatsApp or through the contact page. Send the site elevation, the lowest winter temperature, the highest summer ambient, the required pressure, the target flow, the fuel grade available locally, and the delivery schedule, and you will get a specification review with the derated output at site elevation and the cold-start and cooling packages written against your site numbers rather than ours.